CSA approval Constant Temperature Water Heater Control Board BW-HK002R
gas water heater control board Function description
1) It works with a display.
2) It works with a ventilator.
3) It works with a on-off valve, a proportional valve and a section valve.
4) It is with a buzzer.
5) It has AC ionization flame signal detection.
6) Status keeping function: If the nP menu was set as ON, after power on again, the system
will return to the last status before the power is cut off.
7) Flue pipe block-up protection.
8) Malfunction protection and warning function.
9) Compliance with Standard: BS EN298: 2012. ANSI Z21.20 -2014. CAN/CSA C22.2 No. 60730-2-5-2014.
More information you can click here
Main technical parameters
|
Working voltage range
|
90VAC ~ 120VAC
|
Rated voltage
|
120VAC 60Hz
|
Power frequency
|
50/60Hz±5%
|
Rated frequency
|
50Hz
|
Dielectric strength(V/1min)
|
1800V, 0.5mA, 3S
|
Working ambient temperature
|
-10℃~70℃
|
Ambient temperature
|
-20℃~70℃
|
Life cycle
|
≥50,000 times
|
Temperature setting range
|
35-65℃
|
High temperature protection
|
when the output water temperature ≥85℃ for 3S
|
Pre- cleaning time
|
2S
|
After cleaning time
|
20s
|
Start-up water flow
|
≤3L/min
|
Closing water flow
|
≤2.5L/min
|
Ignition time
|
8±1S
|
Cleaning time before 2nd ignition
|
3S
|
Max. allowable No. of ignition
|
2
|
Valve moving pulse
|
0.5±0.05S
|
24V Valve open voltage
|
≥24V
|
24V Valve holding voltage
|
≥8.5V
|
Output voltage of switch power supply
|
5VDC (with 300mA working current)
|
30±1.5VDC(with 510mA working current)
|
12±1VDC(with 110mA working current)
|
Ion sensibility of flame detection
|
≥5.1MΩ
|
Temperature detection precision
|
±2℃
|
Waiting time of reaching setted temperature
|
≤35S
|
Water temperature overshoot range
|
±3℃
|
Timing tolerance
|
±1 minutes
|
Post-purge time
|
20±2s
|
Time to achieve safe shut down
|
<1s
|
Trial for ignition period
|
7.5±1s
|